<?xml version="1.0" encoding="UTF-8" standalone="yes"?>
<Spase xmlns="http://www.spase-group.org/data/schema" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.spase-group.org/data/schema https://www.spase-group.org/data/schema/spase-2_5_0.xsd">
   <Version>2.5.0</Version>
   <NumericalData>
      <ResourceID>spase://IUGONET/NumericalData/NIPR/Iceland/AED/induction/PT2S_cdf</ResourceID>
      <ResourceHeader>
         <ResourceName>CDF data of magnetic field measured at 2-sec intervals with the induction magnetometer at Aedey, Iceland.</ResourceName>
         <ReleaseDate>2013-07-23T12:00:00</ReleaseDate>
         <Description>Magnetic field measured with the induction magnetometer at Aedey, Iceland. The data consist of variations of three-dimensional (H, D, and Z components) geomagnetic field taken with a sampling rate of 0.5 Hz, and some engineering parameters for the instrument, such as the sensitivity and phase difference. (As of July 2013, the engineering parameters are invalid.) The digital data are distributed in the Common Data Format (CDF).</Description>
         <Acknowledgement>Please contact the Principal Investigator, Dr. Akira Kadokura (kadokura [at] nipr.ac.jp), National Institute of Polar Research (NIPR) before using the data at any publications and/or presentations. We welcome collaborative research and strongly recommend users to contact us early in order to ensure that the data are suitable for their research. When the data are used at any publications and/or presentations, we would like to ask the users to acknowledge NIPR and send us one copy of the reprints. An example of the acknowledgement statement is as follows: &quot;Magnetic field data were provided by National Institute of Polar Research, Japan.&quot;</Acknowledgement>
         <Contact>
            <PersonID>spase://IUGONET/Person/Akira.Kadokura</PersonID>
            <Role>PrincipalInvestigator</Role>
         </Contact>
         <Contact>
            <PersonID>spase://IUGONET/Person/Yuka.Sato</PersonID>
            <Role>MetadataContact</Role>
         </Contact>
      </ResourceHeader>
      <AccessInformation>
         <RepositoryID>spase://IUGONET/Repository/NIPR/IUGONET_DB_NIPR</RepositoryID>
         <Availability>Online</Availability>
         <AccessRights>Open</AccessRights>
         <AccessURL>
            <Name>Conjugate Observation at Iceland</Name>
            <URL>http://scidbase.nipr.ac.jp/modules/metadata/index.php?content_id=115</URL>
         </AccessURL>
         <AccessURL>
            <Name>Conjugate Observation between Syowa Station and Iceland</Name>
            <URL>http://polaris.nipr.ac.jp/~aurora/uapm/ConjugateObsTop.html</URL>
         </AccessURL>
         <AccessURL>
            <Name>IUGONET Database in NIPR</Name>
            <URL>http://iugonet0.nipr.ac.jp/data/</URL>
         </AccessURL>
         <Format>CDF</Format>
      </AccessInformation>
      <ProcessingLevel>Uncalibrated</ProcessingLevel>
      <InstrumentID>spase://IUGONET/Instrument/NIPR/Iceland/AED/induction</InstrumentID>
      <MeasurementType>MagneticField</MeasurementType>
      <TemporalDescription>
         <TimeSpan>
            <StartDate>1989-08-20T00:00:00</StartDate>
            <StopDate>1999-10-18T23:59:58</StopDate>
         </TimeSpan>
         <Cadence>PT2S</Cadence>
      </TemporalDescription>
      <ObservedRegion>Earth.Magnetosphere</ObservedRegion>
      <ObservedRegion>Earth.NearSurface.Ionosphere.ERegion</ObservedRegion>
      <SpatialCoverage>
         <CoordinateSystem>
            <CoordinateRepresentation>Spherical</CoordinateRepresentation>
            <CoordinateSystemName>GEO</CoordinateSystemName>
         </CoordinateSystem>
         <NorthernmostLatitude>66.09</NorthernmostLatitude>
         <SouthernmostLatitude>66.09</SouthernmostLatitude>
         <EasternmostLongitude>-22.65</EasternmostLongitude>
         <WesternmostLongitude>-22.65</WesternmostLongitude>
      </SpatialCoverage>
      <Keyword>EARTH SCIENCE Sun-earch Interaction Ionosphere/Magnetosphere Dynamics Magnetic Fields/Magnetic Currents</Keyword>
      <Parameter>
         <Name>Epoch for the dB/dt data</Name>
         <ParameterKey>epoch_db_dt</ParameterKey>
         <Description>time label in CDF_EPOCH (the number of milliseconds since 01-Jan-0000) for the dB/dt data. All time values are in the universal time.</Description>
         <Units>millisecond</Units>
         <Support>
            <SupportQuantity>Temporal</SupportQuantity>
         </Support>
      </Parameter>
      <Parameter>
         <Name>Observation date and time for the dB/dt data</Name>
         <ParameterKey>time_db_dt</ParameterKey>
         <Description>Observation date and time for the dB/dt data. The time label for each time frame consists of an integer array of 7 elements for Year, month, day, hour, minute, second, milisecond. All time values are in the universal time.</Description>
         <Support>
            <SupportQuantity>Temporal</SupportQuantity>
         </Support>
      </Parameter>
      <Parameter>
         <Name>dB/dt values for 3-component vector magnetogram</Name>
         <ParameterKey>db_dt</ParameterKey>
         <Description>Time derivative of 3-component (dH/dt, dD/dt, and dZ/dt) vector geomagnetic field observed with a sampling rate of 0.5 Hz. The unit is voltage [V], that is, the raw output from the instrument.</Description>
         <Field>
            <FieldQuantity>Magnetic</FieldQuantity>
         </Field>
      </Parameter>
      <Parameter>
         <Name>Pulse signal from the GPS clock associated with the magnetometer</Name>
         <ParameterKey>gps_1pps_time_pulse</ParameterKey>
         <Description>This parameter is invalid for this data.</Description>
         <Support>
            <SupportQuantity>Other</SupportQuantity>
         </Support>
      </Parameter>
      <Parameter>
         <Name>Frequency values for the sensitivity-phase difference table</Name>
         <ParameterKey>frequency</ParameterKey>
         <Description>Frequency values in Hz for the sensitivity-phase difference table for this induction magnetometer. As of July 2013, this parameter is invalid.</Description>
         <Support>
            <SupportQuantity>Other</SupportQuantity>
         </Support>
      </Parameter>
      <Parameter>
         <Name>Sensitivity coefficients for the sensitivity-phase difference table</Name>
         <ParameterKey>sensitivity</ParameterKey>
         <Description>Conversion coefficients in V/nT taking into account the frequency-dependent sensitivity for this induction magnetometer. As of July 2013, this parameter is invalid.</Description>
         <Support>
            <SupportQuantity>Other</SupportQuantity>
         </Support>
      </Parameter>
      <Parameter>
         <Name>Phase difference values for the sensitivity-phase difference table</Name>
         <ParameterKey>phase_difference</ParameterKey>
         <Description>Phase difference in degree for each frequency used for the phase calibration. As of July 2013, this parameter is invalid.</Description>
         <Support>
            <SupportQuantity>Other</SupportQuantity>
         </Support>
      </Parameter>
   </NumericalData>
</Spase>