  "Spase": {
    "xmlns": "http://www.spase-group.org/data/schema",
    "xmlns:xsi": "http://www.w3.org/2001/XMLSchema-instance",
    "xsi:schemaLocation": "http://www.spase-group.org/data/schema https://www.spase-group.org/data/schema/spase-2_5_0.xsd",
    "Version": "2.5.0",
    "NumericalData": {
      "ResourceID": "spase://IUGONET/NumericalData/WDC_Kyoto/WDC/Dst/index/PT1H",
      "ResourceHeader": {
        "ResourceName": "Geomagnetic Equatorial Dst Index",
        "ReleaseDate": "2011-02-17T08:00:00",
        "Description": "The geomagnetic equatorial Dst index at 1-hr time resolution, derived at World Data Center for Geomagnetism, Kyoto, Kyoto University.",
        "Acknowledgement": "If the data are used in publications and presentations, the data suppliers and the WDC for Geomagnetism, Kyoto must properly be acknowledged.",
        "Contact": [
          {
            "PersonID": "spase://IUGONET/Person/Toshihiko.Iyemori",
            "Role": "GeneralContact"
          },
          {
            "PersonID": "spase://IUGONET/Person/Masahito.Nose",
            "Role": "GeneralContact"
          },
          {
            "PersonID": "spase://IUGONET/Person/Yukinobu.Koyama",
            "Role": "MetadataContact"
          }
        ],
        "InformationURL": {
          "Name": "Geomagnetic Equatorial Dst index Home Page",
          "URL": "http://wdc.kugi.kyoto-u.ac.jp/dstdir/index.html",
          "Description": "The web site with links to pages describing the internationally accepted standard technique for generating the Dst Index and for access to the index data in WDC format."
        }
      },
      "AccessInformation": {
        "RepositoryID": "spase://IUGONET/Repository/WDC_Kyoto/WDC",
        "Availability": "Online",
        "AccessRights": "Open",
        "AccessURL": {
          "Name": "Geomagnetic Data Service",
          "URL": "http://wdc.kugi.kyoto-u.ac.jp/wdc/Sec3.html",
          "Description": "Geomagnetic Data Service at World Data Center for Geomagnetism, Kyoto."
        },
        "Format": "Text",
        "Encoding": "ASCII",
        "Acknowledgement": "If the data are used in publications and presentations, the data suppliers and the WDC for Geomagnetism, Kyoto must properly be acknowledged."
      },
      "ProcessingLevel": "Calibrated",
      "InstrumentID": [
        "spase://IUGONET/Instrument/WDC_Kyoto/WDC/HER/Magnetometer",
        "spase://IUGONET/Instrument/WDC_Kyoto/WDC/KAK/Magnetometer",
        "spase://IUGONET/Instrument/WDC_Kyoto/WDC/HON/Magnetometer",
        "spase://IUGONET/Instrument/WDC_Kyoto/WDC/SJG/Magnetometer"
      ],
      "MeasurementType": "ActivityIndex",
      "TemporalDescription": {
        "TimeSpan": {
          "StartDate": "1957-01-01T00:00:00",
          "StopDate": "2011-12-31T00:00:00"
        },
        "Cadence": "PT1H"
      },
      "ObservedRegion": "Earth.Surface",
      "SpatialCoverage": {
        "CoordinateSystem": {
          "CoordinateRepresentation": "Spherical",
          "CoordinateSystemName": "GEO"
        },
        "NorthernmostLatitude": "36.233",
        "SouthernmostLatitude": "-34.425",
        "EasternmostLongitude": "180",
        "WesternmostLongitude": "-180"
      },
      "Keyword": "Geomagnetic Indices",
      "Parameter": [
        {
          "Name": "Universal Time",
          "Description": "Time is expressed with year, month, day, and hour, each stored in integer format. Details of the data record format is described at http://wdc.kugi.kyoto-u.ac.jp/dstae/format/dstformat.html",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "(UT)",
            "ScaleType": "LinearScale"
          },
          "Support": {
            "SupportQuantity": "Temporal"
          }
        },
        {
          "Name": "Geomagnetic Equatorial Dst index",
          "ParameterKey": "Dst",
          "Description": "The Dst index is calculated by the sum of base value (unit 100nT) and 24 hourly value (unit 1nT). Details of the data record format is described at http://wdc.kugi.kyoto-u.ac.jp/dstae/format/dstformat.html",
          "Cadence": "PT1H",
          "Units": "nT",
          "RenderingHints": {
            "DisplayType": "TimeSeries",
            "AxisLabel": "(nT)",
            "ScaleMin": "-500",
            "ScaleMax": "100",
            "ScaleType": "LinearScale"
          },
          "FillValue": "9999",
          "Field": {
            "Qualifier": "Scalar",
            "FieldQuantity": "Magnetic"
          }
        }
      ]
    }
  }
}