  "id": "C4_PP_RAP",
  "url": "http://hpde.io/ESA/NumericalData/Cluster-Tango/RAPID/PrimeParameter/PT4S",
  "data-file": "./data/spase_hpde_io/info/C4_PP_RAP.json",
  "data": {
    "Spase": {
      "xmlns": "http://www.spase-group.org/data/schema",
      "xmlns:xsi": "http://www.w3.org/2001/XMLSchema-instance",
      "xsi:schemaLocation": "http://www.spase-group.org/data/schema  http://www.spase-group.org/data/schema/spase-2_3_0.xsd'",
      "Version": "2.3.0",
      "NumericalData": {
        "ResourceID": "spase://ESA/NumericalData/Cluster-Tango/RAPID/PrimeParameter/PT4S",
        "ResourceHeader": {
          "ResourceName": "Cluster-Tango Prime Parameter Research with Adaptive Particle Imaging Detectors (RAPID) Data",
          "AlternateName": "Cluster 4 Prime Parameter RAPID Data",
          "ReleaseDate": "2021-04-27T17:52:14Z",
          "Description": "The dual-sensor spectrometer RAPID (Research with Adaptive Particle Imaging Detectors) analyzes suprathermal plasma distributions in the energy range from 20-400 KeV for electrons and from 2 KeV/nucleon to 1.50 MeV/nucleon for ions. For more details of the Cluster mission, the spacecraft, and its instruments, see the report Cluster: mission, payload and supporting activities, March 1993, ESA SP-1159, and the included article RAPID: The Imaging Energetic Particle Spectrometer on Cluster, by B. Wilken et al., from which this information was obtained.",
          "Acknowledgement": "NASA, Dr. Berend Wilken, European Space Agency",
          "Contact": [
            {
              "PersonID": "spase://SMWG/Person/Berend.Wilken",
              "Role": "PrincipalInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/Joseph.F.Fennell",
              "Role": "CoInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/J.Bernard.Blake",
              "Role": "CoInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/Finn.Soraas",
              "Role": "CoInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/Bengt.K.G.Hultqvist",
              "Role": "CoInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/Richard.D.Belian",
              "Role": "CoInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/Theodore.Allan.Fritz",
              "Role": "CoInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/Axel.Korth",
              "Role": "CoInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/Hans.Borg",
              "Role": "CoInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/Pekka.J.Tanskanen",
              "Role": "CoInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/Gerhard.Kremser",
              "Role": "CoInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/David.S.Hall",
              "Role": "CoInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/Stein.Ullaland",
              "Role": "CoInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/Daniel.N.Baker",
              "Role": "CoInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/Fritz.O.Gliem",
              "Role": "CoInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/Peter.W.Daly",
              "Role": "CoInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/Susan.M.P.McKenna-Lawlor",
              "Role": "CoInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/Stefano.A.Livi",
              "Role": "CoInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/Kalevi.Mursula",
              "Role": "CoInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/Manuel.Grande",
              "Role": "CoInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/James.M.Weygand",
              "Role": "MetadataContact"
            }
          ],
          "InformationURL": {
            "Name": "NSSDC Master Catalog listing for Cluster II Tango Research with Adaptive Particle Imaging Detectors (RAPID)",
            "URL": "https://nssdc.gsfc.nasa.gov/nmc/experiment/display.action?id=2000-045B-06",
            "Description": "This site provides information concerning the Cluster II Tango Research with Adaptive Particle Imaging Detectors Instrument."
          },
          "Association": {
            "AssociationID": "spase://SMWG/Observatory/Cluster-Tango",
            "AssociationType": "ObservedBy"
          },
          "PriorID": [
            "spase://VMO/NumericalData/Cluster2-Tango/RAPID/PrimeParameter/4S",
            "spase://VMO/NumericalData/Cluster-Tango/RAPID/PrimeParameter/4S",
            "spase://VSPO/NumericalData/Cluster-Tango/RAPID/PrimeParameter/PT4S"
          ]
        },
        "AccessInformation": [
          {
            "RepositoryID": "spase://SMWG/Repository/NASA/GSFC/SPDF/CDAWeb",
            "Availability": "Online",
            "AccessRights": "Open",
            "AccessURL": {
              "Name": "FTPS from SPDF (not with most browsers)",
              "URL": "ftps://spdf.gsfc.nasa.gov/pub/data/cluster/c4/pp/rap/",
              "Description": "Cluster II Tango Prime Parameter Research with Adaptive Particle Imaging Detectors (RAPID) data"
            },
            "Format": "CDF",
            "Acknowledgement": "NASA, Dr. Berend Wilken"
          },
          {
            "RepositoryID": "spase://SMWG/Repository/NASA/GSFC/SPDF/CDAWeb",
            "Availability": "Online",
            "AccessRights": "Open",
            "AccessURL": {
              "Name": "HTTPS from SPDF",
              "URL": "https://spdf.gsfc.nasa.gov/pub/data/cluster/c4/pp/rap/",
              "Description": "In CDF via HTTP from SPDF"
            },
            "Format": "CDF",
            "Acknowledgement": "NASA, Dr. Berend Wilken"
          },
          {
            "RepositoryID": "spase://SMWG/Repository/NASA/GSFC/SPDF/CDAWeb",
            "Availability": "Online",
            "AccessRights": "Open",
            "AccessURL": {
              "Name": "CDAWeb",
              "URL": "https://cdaweb.gsfc.nasa.gov/cgi-bin/eval2.cgi?dataset=C4_PP_RAP&index=sp_phys",
              "ProductKey": "C4_PP_RAP"
            },
            "Format": "CDF",
            "Acknowledgement": "NASA, Dr. Berend Wilken"
          },
          {
            "RepositoryID": "spase://SMWG/Repository/NASA/GSFC/SPDF",
            "Availability": "Online",
            "AccessRights": "Open",
            "AccessURL": {
              "Name": "CDAWeb HAPI Server",
              "URL": "https://cdaweb.gsfc.nasa.gov/hapi",
              "Style": "HAPI",
              "ProductKey": "C4_PP_RAP",
              "Description": "Web Service to this product using the HAPI interface."
            },
            "Format": "CSV",
            "Acknowledgement": "NASA, Dr. Berend Wilken"
          }
        ],
        "ProcessingLevel": "Calibrated",
        "ProviderResourceName": "Cluster II Tango Prime Parameter Research with Adaptive Particle Imaging Detectors (RAPID) Data",
        "ProviderProcessingLevel": "Calibrated",
        "ProviderVersion": "1",
        "InstrumentID": "spase://SMWG/Instrument/Cluster-Tango/RAPID",
        "MeasurementType": "EnergeticParticles",
        "TemporalDescription": {
          "TimeSpan": {
            "StartDate": "2000-12-09T00:00:00",
            "RelativeStopDate": "-P3M",
            "Note": "Time format in data files is: day, month, year hour, min, seconds. Ex: 01-Jan-1981 00:00:00.000"
          },
          "Cadence": "PT4S"
        },
        "ObservedRegion": [
          "Earth.Magnetosheath",
          "Earth.Magnetosphere",
          "Earth.Magnetosphere.Magnetotail",
          "Earth.Magnetosphere.Main",
          "Earth.Magnetosphere.Polar",
          "Earth.Magnetosphere.RadiationBelt",
          "Earth.NearSurface.AuroralRegion",
          "Earth.NearSurface.Ionosphere",
          "Earth.NearSurface.Plasmasphere",
          "Earth.NearSurface.PolarCap",
          "Heliosphere.NearEarth"
        ],
        "Keyword": [
          "4 second",
          "magnetosphere",
          "auroral region",
          "polar cap",
          "cusp",
          "bow shock",
          "solar wind",
          "magnetosheath",
          "Cluster",
          "magnetotail",
          "lobe"
        ],
        "Parameter": {
          "Half_interval__C4_PP_RAP": {
            "Name": "Half Sample Time Interval",
            "ParameterKey": "Half_interval__C4_PP_RAP",
            "Description": "Half width of measurement interval",
            "Cadence": "PT4S",
            "Units": "ms",
            "UnitsConversion": "1.0e-3>s",
            "FillValue": "-1.0000e+31",
            "Support": {
              "SupportQuantity": "Other"
            }
          },
          "Epoch__C4_PP_RAP": {
            "Name": "Universal Time",
            "ParameterKey": "Epoch__C4_PP_RAP",
            "Description": "Universal Time in data cell: day, month, year hour, min, seconds. Ex: 01-Jan-1981 00:00:00.000.",
            "Cadence": "PT4S",
            "Units": "ms",
            "UnitsConversion": "1.0e-3>s",
            "RenderingHints": {
              "AxisLabel": "Epoch"
            },
            "FillValue": "-1.0000e+31",
            "Support": {
              "SupportQuantity": "Temporal"
            }
          },
          "Status__C4_PP_RAP": {
            "Name": "Status",
            "ParameterKey": "Status__C4_PP_RAP",
            "Description": "Cluster II Tango Prime Parameter Research with Adaptive Particle Imaging Detectors status at spin time resolution",
            "Cadence": "PT4S",
            "ValidMin": "0",
            "ValidMax": "255",
            "FillValue": "255",
            "Support": {
              "SupportQuantity": "Other"
            }
          },
          "J_e_lo__C4_PP_RAP": {
            "Name": "Electron Flux (E>50 keV)",
            "ParameterKey": "J_e_lo__C4_PP_RAP",
            "Description": "Cluster II Tango Prime Parameter Research with Adaptive Particle Imaging Detectors electron flux for electrons with energies greater than 50 keV at spin time resolution",
            "Cadence": "PT4S",
            "Units": "1/(cm^2 s sr)",
            "UnitsConversion": "1.e4>m^-2 s^-1 sr^-1",
            "RenderingHints": {
              "AxisLabel": "J(e,lo)",
              "ScaleMin": "100",
              "ScaleMax": "10000000"
            },
            "ValidMin": "0",
            "ValidMax": "2.0000e+9",
            "FillValue": "-1.0000e+31",
            "Particle": {
              "ParticleType": "Electron",
              "Qualifier": "Scalar",
              "ParticleQuantity": "EnergyFlux"
            }
          },
          "J_e_hi__C4_PP_RAP": {
            "Name": "Electron Flux (E>95 keV)",
            "ParameterKey": "J_e_hi__C4_PP_RAP",
            "Description": "Cluster II Tango Prime Parameter Research with Adaptive Particle Imaging Detectors electron flux for electrons with energies greater than 95 keV at spin time resolution",
            "Cadence": "PT4S",
            "Units": "1/(cm^2 s sr)",
            "UnitsConversion": "1.e4>m^-2 s^-1 sr^-1",
            "RenderingHints": {
              "AxisLabel": "J(e,hi)",
              "ScaleMin": "100",
              "ScaleMax": "10000000"
            },
            "ValidMin": "0",
            "ValidMax": "2.0000e+9",
            "FillValue": "-1.0000e+31",
            "Particle": {
              "ParticleType": "Electron",
              "Qualifier": "Scalar",
              "ParticleQuantity": "EnergyFlux"
            }
          },
          "J_p_lo__C4_PP_RAP": {
            "Name": "Proton Flux (E>28 keV)",
            "ParameterKey": "J_p_lo__C4_PP_RAP",
            "Description": "Cluster II Tango Prime Parameter Research with Adaptive Particle Imaging Detectors proton flux for protons with energies greater than 28 keV at spin time resolution",
            "Cadence": "PT4S",
            "Units": "1/(cm^2 s sr)",
            "UnitsConversion": "1.e4>m^-2 s^-1 sr^-1",
            "RenderingHints": {
              "AxisLabel": "J(p,lo)",
              "ScaleMin": "100",
              "ScaleMax": "10000000"
            },
            "ValidMin": "0",
            "ValidMax": "2.0000e+9",
            "FillValue": "-1.0000e+31",
            "Particle": {
              "ParticleType": "Proton",
              "Qualifier": "Scalar",
              "ParticleQuantity": "EnergyFlux"
            }
          },
          "J_p_hi__C4_PP_RAP": {
            "Name": "Proton Flux (E>92 keV)",
            "ParameterKey": "J_p_hi__C4_PP_RAP",
            "Description": "Cluster II Tango Prime Parameter Research with Adaptive Particle Imaging Detectors proton flux for protons with energies greater than 92 keV at spin time resolution",
            "Cadence": "PT4S",
            "Units": "1/(cm^2 s sr)",
            "UnitsConversion": "1.e4>m^-2 s^-1 sr^-1",
            "RenderingHints": {
              "AxisLabel": "J(p,lo)",
              "ScaleMin": "100",
              "ScaleMax": "10000000"
            },
            "ValidMin": "0",
            "ValidMax": "2.0000e+9",
            "FillValue": "-1.0000e+31",
            "Particle": {
              "ParticleType": "Proton",
              "Qualifier": "Scalar",
              "ParticleQuantity": "EnergyFlux"
            }
          },
          "J_He_lo__C4_PP_RAP": {
            "Name": "Helium Flux (E>138 kev)",
            "ParameterKey": "J_He_lo__C4_PP_RAP",
            "Description": "Cluster II Tango Prime Parameter Research with Adaptive Particle Imaging Detectors helium flux for helium with energies greater than 138 keV at spin time resolution",
            "Cadence": "PT4S",
            "Units": "1/(cm^2 s sr)",
            "UnitsConversion": "1.e4>m^-2 s^-1 sr^-1",
            "RenderingHints": {
              "AxisLabel": "J(He,lo)",
              "ScaleMin": "100",
              "ScaleMax": "10000000"
            },
            "ValidMin": "0",
            "ValidMax": "2.0000e+9",
            "FillValue": "-1.0000e+31",
            "Particle": {
              "ParticleType": "AlphaParticle",
              "Qualifier": "Scalar",
              "ParticleQuantity": "EnergyFlux"
            }
          },
          "J_He_hi__C4_PP_RAP": {
            "Name": "Helium Flux (E>172 kev)",
            "ParameterKey": "J_He_hi__C4_PP_RAP",
            "Description": "Cluster II Tango Prime Parameter Research with Adaptive Particle Imaging Detectors helium flux for helium with energies greater than 172 keV at spin time resolution",
            "Cadence": "PT4S",
            "Units": "1/(cm^2 s sr)",
            "UnitsConversion": "1.e4>m^-2 s^-1 sr^-1",
            "RenderingHints": {
              "AxisLabel": "J(He,hi)",
              "ScaleMin": "100",
              "ScaleMax": "10000000"
            },
            "ValidMin": "0",
            "ValidMax": "2.0000e+9",
            "FillValue": "-1.0000e+31",
            "Particle": {
              "ParticleType": "AlphaParticle",
              "Qualifier": "Scalar",
              "ParticleQuantity": "EnergyFlux"
            }
          },
          "J_hvy_lo__C4_PP_RAP": {
            "Name": "Ion Flux (m>4, E>84 kev)",
            "ParameterKey": "J_hvy_lo__C4_PP_RAP",
            "Description": "Cluster II Tango Prime Parameter Research with Adaptive Particle Imaging Detectors ion flux for ions with energies greater than 84 keV and atomic mass greater than 4 at spin time resolution",
            "Cadence": "PT4S",
            "Units": "1/(cm^2 s sr)",
            "UnitsConversion": "1.e4>m^-2 s^-1 sr^-1",
            "RenderingHints": {
              "AxisLabel": "J(m>4,lo)",
              "ScaleMin": "100",
              "ScaleMax": "10000000"
            },
            "ValidMin": "0",
            "ValidMax": "2.0000e+9",
            "FillValue": "-1.0000e+31",
            "Particle": {
              "ParticleType": "Ion",
              "Qualifier": "Scalar",
              "ParticleQuantity": "EnergyFlux"
            }
          },
          "J_hvy_hi__C4_PP_RAP": {
            "Name": "Ion Flux (m>4, E>414 kev)",
            "ParameterKey": "J_hvy_hi__C4_PP_RAP",
            "Description": "Cluster II Tango Prime Parameter Research with Adaptive Particle Imaging Detectors ion flux for ions with energies greater than 414 keV and atomic mass greater than 4 at spin time resolution",
            "Cadence": "PT4S",
            "Units": "1/(cm^2 s sr)",
            "UnitsConversion": "1.e4>m^-2 s^-1 sr^-1",
            "RenderingHints": {
              "AxisLabel": "J(m>4,hi)",
              "ScaleMin": "100",
              "ScaleMax": "10000000"
            },
            "ValidMin": "0",
            "ValidMax": "2.0000e+9",
            "FillValue": "-1.0000e+31",
            "Particle": {
              "ParticleType": "Ion",
              "Qualifier": "Scalar",
              "ParticleQuantity": "EnergyFlux"
            }
          },
          "A_e_par__C4_PP_RAP": {
            "Name": "Field-Aligned Electron Anisotropy",
            "ParameterKey": "A_e_par__C4_PP_RAP",
            "Description": "Cluster II Tango Prime Parameter Research with Adaptive Particle Imaging Detectors field-aligned electron anisotropy at spin time resolution",
            "Cadence": "PT4S",
            "RenderingHints": {
              "AxisLabel": "A(e)",
              "ScaleMin": "-1",
              "ScaleMax": "1"
            },
            "ValidMin": "-1",
            "ValidMax": "1",
            "FillValue": "-1.0000e+31",
            "Support": {
              "SupportQuantity": "Other"
            }
          },
          "A_p_par__C4_PP_RAP": {
            "Name": "Field-Aligned Proton Anisotropy",
            "ParameterKey": "A_p_par__C4_PP_RAP",
            "Description": "Cluster II Tango Prime Parameter Research with Adaptive Particle Imaging Detectors field-aligned proton anisotropy at spin time resolution",
            "Cadence": "PT4S",
            "RenderingHints": {
              "AxisLabel": "A(e)",
              "ScaleMin": "-1",
              "ScaleMax": "1"
            },
            "ValidMin": "-1",
            "ValidMax": "1",
            "FillValue": "-1.0000e+31",
            "Support": {
              "SupportQuantity": "Other"
            }
          }
        }
      }
    }
  }
}