  "id": "MMS1_EDP_FAST_L2_DCE",
  "url": "http://hpde.io/VSPO/NumericalData/MMS/1/FIELDS/EDP/Fast/Level2/DCElectricField/PT0.03125S",
  "data-file": "./data/spase_hpde_io/info/MMS1_EDP_FAST_L2_DCE.json",
  "data": {
    "Spase": {
      "xmlns": "http://www.spase-group.org/data/schema",
      "Version": "2.2.6",
      "NumericalData": {
        "ResourceID": "spase://VSPO/NumericalData/MMS/1/FIELDS/EDP/Fast/Level2/DCElectricField/PT0.03125S",
        "ResourceHeader": {
          "ResourceName": "MMS 1 Electric Double Probe (EDP) Three-Dimensional Electric Field, Quick-Look, Fast Survey",
          "ReleaseDate": "2020-07-03T23:28:58Z",
          "Description": "Electric Double Probe, Quick-Look Three-Dimensional Electric Field, Level 2, Fast Survey Data",
          "Acknowledgement": "J. Burch, R. Ergun, P. Lindqvist",
          "Contact": [
            {
              "PersonID": "spase://SMWG/Person/James.L.Burch",
              "Role": "PrincipalInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/Robert.E.Ergun",
              "Role": "PrincipalInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/Per-Arne.Lindqvist",
              "Role": "PrincipalInvestigator"
            },
            {
              "PersonID": "spase://SMWG/Person/Robert.E.McGuire",
              "Role": "MetadataContact"
            },
            {
              "PersonID": "spase://SMWG/Person/Lee.Frost.Bargatze",
              "Role": "MetadataContact"
            }
          ],
          "InformationURL": {
            "Name": "At NASA GSFC",
            "URL": "https://mms.gsfc.nasa.gov/",
            "Description": "Magnetospheric Multiscale (MMS) mission home page"
          }
        },
        "AccessInformation": [
          {
            "RepositoryID": "spase://SMWG/Repository/NASA/GSFC/SPDF",
            "Availability": "Online",
            "AccessRights": "Open",
            "AccessURL": {
              "Name": "FTPS from SPDF (not with most browsers)",
              "URL": "ftps://spdf.gsfc.nasa.gov/pub/data/mms/mms1/edp/fast/l2/dce/",
              "Description": "In CDF via ftp from SPDF."
            },
            "Format": "CDF",
            "Encoding": "None",
            "Acknowledgement": "J. Burch, R. Ergun, P. Lindqvist. Please acknowledge the data providers and CDAWeb when using these data."
          },
          {
            "RepositoryID": "spase://SMWG/Repository/NASA/GSFC/SPDF",
            "Availability": "Online",
            "AccessRights": "Open",
            "AccessURL": {
              "Name": "HTTPS from SPDF",
              "URL": "https://spdf.gsfc.nasa.gov/pub/data/mms/mms1/edp/fast/l2/dce/",
              "Description": "In CDF via http from SPDF."
            },
            "Format": "CDF",
            "Encoding": "None",
            "Acknowledgement": "J. Burch, R. Ergun, P. Lindqvist. Please acknowledge the data providers and CDAWeb when using these data."
          },
          {
            "RepositoryID": "spase://SMWG/Repository/NASA/GSFC/SPDF",
            "Availability": "Online",
            "AccessRights": "Open",
            "AccessURL": {
              "Name": "CDAWeb",
              "URL": "https://cdaweb.sci.gsfc.nasa.gov/cgi-bin/eval2.cgi?dataset=MMS1_EDP_FAST_L2_DCE&index=sp_phys",
              "ProductKey": "MMS1_EDP_FAST_L2_DCE",
              "Description": "Access to ASCII, CDF, and plots via NASA/GSFC CDAWeb"
            },
            "Format": "CDF",
            "Encoding": "None",
            "Acknowledgement": "J. Burch, R. Ergun, P. Lindqvist. Please acknowledge the data providers and CDAWeb when using these data."
          }
        ],
        "ProcessingLevel": "Calibrated",
        "InstrumentID": [
          "spase://SMWG/Instrument/MMS/1/FIELDS/ADP",
          "spase://SMWG/Instrument/MMS/1/FIELDS/SDP"
        ],
        "MeasurementType": "ElectricField",
        "TemporalDescription": {
          "TimeSpan": {
            "StartDate": "2015-08-28T00:00:00.000",
            "RelativeStopDate": "-P2M"
          },
          "Cadence": "PT0.03125S"
        },
        "ObservedRegion": [
          "Earth.Magnetosheath",
          "Earth.Magnetosphere",
          "Earth.Magnetosphere.Magnetotail",
          "Earth.Magnetosphere.Main",
          "Earth.Magnetosphere.RadiationBelt",
          "Earth.NearSurface.EquatorialRegion",
          "Earth.NearSurface.Plasmasphere",
          "Heliosphere.NearEarth"
        ],
        "Parameter": {
          "mms1_edp_epoch_fast_l2": {
            "Name": "Epoch Time",
            "ParameterKey": "mms1_edp_epoch_fast_l2",
            "Description": "Epoch Time Tags, Interval Centered, in Terrestrial Time 2000 (TT2000)",
            "Caveats": "This parameter exhibits an increasing monotonic progression.",
            "Cadence": "PT0.03125S",
            "Units": "ns",
            "UnitsConversion": "1.0e-9>s",
            "ValidMin": "1990-01-01T00:00:00.000000000",
            "ValidMax": "2100-01-01T00:00:01.000000000",
            "FillValue": "9999-12-31T23:59:59.999999999",
            "Support": {
              "SupportQuantity": "Temporal"
            }
          },
          "mms1_edp_dce_gse_fast_l2": {
            "Name": "ADP and SDP Calibrated DC Electric Field (GSE)",
            "Set": "Time series defined by using: MMS1_EDP_EPOCH_FAST_L2",
            "ParameterKey": "mms1_edp_dce_gse_fast_l2",
            "Description": "Axial Double Probe (ADP) and Spin-Plane Double Probe (SDP) Calibrated DC Electric Field, Geocentric Solar Ecliptic (GSE) Coordinates, Level 2, Fast Survey",
            "Cadence": "PT0.03125S",
            "Units": "mV/m",
            "UnitsConversion": "1.0e-3>V m^-1",
            "CoordinateSystem": {
              "CoordinateRepresentation": "Cartesian",
              "CoordinateSystemName": "GSE"
            },
            "RenderingHints": {
              "DisplayType": "TimeSeries",
              "ValueFormat": "f8.3"
            },
            "Structure": {
              "Size": "3",
              "Element": [
                {
                  "Name": "Ex",
                  "Index": "1"
                },
                {
                  "Name": "Ey",
                  "Index": "2"
                },
                {
                  "Name": "Ez",
                  "Index": "3"
                }
              ]
            },
            "ValidMin": "-700.0",
            "ValidMax": "700.0",
            "FillValue": "-1.0e+31",
            "Field": {
              "Qualifier": "Vector",
              "FieldQuantity": "Electric"
            }
          },
          "mms1_edp_dce_dsl_fast_l2": {
            "Name": "ADP and SDP Calibrated DC Electric Field (DSL)",
            "Set": "Time series defined by using: MMS1_EDP_EPOCH_FAST_L2",
            "ParameterKey": "mms1_edp_dce_dsl_fast_l2",
            "Description": "Axial Double Probe (ADP) and Spin-Plane Double Probe (SDP) Calibrated DC Electric Field, Despun Angular Momentum (DSL) Coordinates, Level 2, Fast Survey",
            "Cadence": "PT0.03125S",
            "Units": "mV/m",
            "UnitsConversion": "1.0e-3>V m^-1",
            "CoordinateSystem": {
              "CoordinateRepresentation": "Cartesian",
              "CoordinateSystemName": "SC"
            },
            "RenderingHints": {
              "DisplayType": "TimeSeries",
              "ValueFormat": "f8.3"
            },
            "Structure": {
              "Size": "3",
              "Element": [
                {
                  "Name": "Ex",
                  "Index": "1"
                },
                {
                  "Name": "Ey",
                  "Index": "2"
                },
                {
                  "Name": "Ez",
                  "Index": "3"
                }
              ]
            },
            "ValidMin": "-700.0",
            "ValidMax": "700.0",
            "FillValue": "-1.0e+31",
            "Field": {
              "Qualifier": "Vector",
              "FieldQuantity": "Electric"
            }
          },
          "mms1_edp_dce_dsl_res_fast_l2": {
            "Name": "Electric Field Difference, L2 Output to L1 input (DSL)",
            "Set": "Time series defined by using: MMS1_EDP_EPOCH_FAST_L2",
            "ParameterKey": "mms1_edp_dce_dsl_res_fast_l2",
            "Description": "Electric Field Difference between the L2, output and the L1 input, Despun Angular Momentum (DSL) Coordinates, Level 2, Fast Survey",
            "Cadence": "PT0.03125S",
            "Units": "mV/m",
            "UnitsConversion": "1.0e-3>V m^-1",
            "CoordinateSystem": {
              "CoordinateRepresentation": "Cartesian",
              "CoordinateSystemName": "SC"
            },
            "RenderingHints": {
              "DisplayType": "TimeSeries",
              "ValueFormat": "f8.3"
            },
            "Structure": {
              "Size": "3",
              "Element": [
                {
                  "Name": "Ex",
                  "Index": "1"
                },
                {
                  "Name": "Ey",
                  "Index": "2"
                },
                {
                  "Name": "Ez",
                  "Index": "3"
                }
              ]
            },
            "ValidMin": "-700.0",
            "ValidMax": "700.0",
            "FillValue": "-1.0e+31",
            "Field": {
              "Qualifier": "Vector",
              "FieldQuantity": "Electric"
            }
          },
          "mms1_edp_dce_err_fast_l2": {
            "Name": "DC Electric Field Error Estimate",
            "Set": "Time series defined by using: MMS1_EDP_EPOCH_FAST_L2",
            "ParameterKey": "mms1_edp_dce_err_fast_l2",
            "Description": "Approximate DC Electric Field Error derived from the Spine Plane DoubleProbe (SDP) Quality and Bitmask and the Axial Double Probe (ADP) Residue Data, Level 2, Fast Survey",
            "Cadence": "PT0.03125S",
            "Units": "mV/m",
            "UnitsConversion": "1.0e-3>V m^-1",
            "RenderingHints": {
              "DisplayType": "TimeSeries",
              "ValueFormat": "f8.3"
            },
            "Structure": {
              "Size": "3",
              "Element": [
                {
                  "Name": "Ex",
                  "Index": "1"
                },
                {
                  "Name": "Ey",
                  "Index": "2"
                },
                {
                  "Name": "Ez",
                  "Index": "3"
                }
              ]
            },
            "ValidMin": "-700.0",
            "ValidMax": "700.0",
            "FillValue": "-1.0e+31",
            "Field": {
              "Qualifier": "Uncertainty",
              "FieldQuantity": "Electric"
            }
          },
          "mms1_edp_bitmask_fast_l2": {
            "Name": "Status Bitmask",
            "Set": "Time series defined by using: MMS1_EDP_EPOCH_FAST_L2",
            "ParameterKey": "mms1_edp_bitmask_fast_l2",
            "Description": "Status Bitmask, Values Used: Bitmask & 0x001: True when probe(s) are disabled, Bitmask & 0x002: True when probe(s) have bad bias settings, Bitmask & 0x004: True when probe(s) are saturated, Bitmask & 0x008: True when probe(s) are saturated due to low density, Bitmask & 0x016: True when probe(s) are sweeping bias, Bitmask & 0x032: True when SDP probe(s) are in shadow from the ADP booms, Bitmask & 0x064: True when ASPOC is emitting non-zero current",
            "Cadence": "PT0.03125S",
            "RenderingHints": {
              "ValueFormat": "i7"
            },
            "ValidMin": "0",
            "ValidMax": "65534",
            "FillValue": "65535",
            "Support": {
              "SupportQuantity": "Other"
            }
          },
          "mms1_edp_quality_fast_l2": {
            "Name": "Data Quality indicator",
            "Set": "Time series defined by using: MMS1_EDP_EPOCH_FAST_L2",
            "ParameterKey": "mms1_edp_quality_fast_l2",
            "Description": "Data Quality Indicator: 4, Best; 3, Good; 2, Data OK, Use with some Caution; 1, Bad Data, Use with Caution; 0, Really Bad Data or No Data",
            "Cadence": "PT0.03125S",
            "RenderingHints": {
              "ValueFormat": "i7"
            },
            "ValidMin": "0",
            "ValidMax": "4",
            "FillValue": "255",
            "Support": {
              "SupportQuantity": "Other"
            }
          },
          "mms1_edp_deltap_fast_l2": {
            "Name": "Epoch Time Delta Plus/Minus",
            "ParameterKey": "mms1_edp_deltap_fast_l2",
            "Description": "The Time Interval of Data Measurements is given by the Epoch Time Tags and Delta Plus/Minus",
            "Cadence": "PT0.03125S",
            "Units": "ns",
            "UnitsConversion": "1.0e-9>s",
            "RenderingHints": {
              "ValueFormat": "f20.6"
            },
            "ValidMin": "61000.0",
            "ValidMax": "6.25e+07",
            "FillValue": "-1.0e+31",
            "Support": {
              "SupportQuantity": "Temporal"
            }
          }
        }
      }
    }
  }
}